Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 12 de 12
1.
Catheter Cardiovasc Interv ; 103(6): 1023-1034, 2024 May.
Article En | MEDLINE | ID: mdl-38639143

BACKGROUND: The clinical efficacy and safety of alcohol septal ablation (ASA) for obstructive hypertrophic cardiomyopathy (HCM) have been well-established; however, less is known about outcomes in patients undergoing preemptive ASA before transcatheter mitral valve replacement (TMVR). AIMS: The goal of this study is to characterize the procedural characteristics and examine the clinical outcomes of ASA in both HCM and pre-TMVR. METHODS: This retrospective study compared procedural characteristics and outcomes in patient who underwent ASA for HCM and TMVR. RESULTS: In total, 137 patients were included, 86 in the HCM group and 51 in the TMVR group. The intraventricular septal thickness (mean 1.8 vs. 1.2 cm; p < 0.0001) and the pre-ASA LVOT gradient (73.6 vs. 33.8 mmHg; p ≤ 0.001) were higher in the HCM group vs the TMVR group. The mean volume of ethanol injected was higher (mean 2.4 vs. 1.7 cc; p < 0.0001). The average neo-left ventricular outflow tract area increased significantly after ASA in the patients undergoing TMVR (99.2 ± 83.37 mm2 vs. 196.5 ± 114.55 mm2; p = <0.0001). The HCM group had a greater reduction in the LVOT gradient after ASA vs the TMVR group (49.3 vs. 18 mmHg; p = 0.0040). The primary composite endpoint was higher in the TMVR group versus the HCM group (50.9% vs. 25.6%; p = 0.0404) and had a higher incidence of new permanent pacemaker (PPM) (25.5% vs. 18.6%; p = 0.3402). The TMVR group had a higher rate of all-cause mortality (9.8% vs. 1.2%; p = 0.0268). CONCLUSIONS: Preemptive ASA before TMVR was performed in patients with higher degree of clinical comorbidities, and correspondingly is associated with worse short-term clinical outcomes in comparison to ASA for HCM patients. ASA before TMVR enabled percutaneous mitral interventions in a small but significant minority of patients that would have otherwise been excluded. The degree of LVOT and neoLVOT area increase is significant and predictable.


Ablation Techniques , Cardiac Catheterization , Cardiomyopathy, Hypertrophic , Ethanol , Heart Valve Prosthesis Implantation , Mitral Valve , Humans , Retrospective Studies , Male , Ethanol/administration & dosage , Ethanol/adverse effects , Cardiomyopathy, Hypertrophic/diagnostic imaging , Cardiomyopathy, Hypertrophic/mortality , Cardiomyopathy, Hypertrophic/therapy , Cardiomyopathy, Hypertrophic/surgery , Cardiomyopathy, Hypertrophic/physiopathology , Female , Treatment Outcome , Ablation Techniques/adverse effects , Ablation Techniques/mortality , Aged , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Cardiac Catheterization/instrumentation , Middle Aged , Risk Factors , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/mortality , Time Factors , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve/surgery , Recovery of Function , Aged, 80 and over , Heart Septum/diagnostic imaging , Heart Septum/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/mortality
2.
Article En | MEDLINE | ID: mdl-38670866

BACKGROUND: Aortic valve lithotripsy can fragment aortic valve calcium deposits and potentially restore leaflet pliability in animal model and ex-vivo, but clinical data is limited. Transcatheter aortic valve implantation (TAVR) might not be feasible as an urgent procedure in critically ill patients. Balloon valvuloplasty has the major limitation of valve recoil and inducing aortic regurgitation. AIMS: To determine the clinical feasibility of aortic valve lithotripsy-facilitated balloon valvuloplasty in patients with severe aortic stenosis unsuitable for valvular replacement. METHODS: We performed lithotripsy as adjunctive therapy to balloon aortic valvuloplasty in ten consecutive patients, most of whom were deemed unfit for TAVR. Lithotripsy of the aortic valve was performed with simultaneous inflation of one to three peripheral lithotripsy balloons to deliver ultrasound pulses. Rapid pacing was not used during lithotripsy. Aortic valve velocity, gradient, and valve area were measured before and after the procedure by echocardiogram. Transvalvular pressure gradient was recorded intra-procedurally. Periprocedural and ninety-day clinical outcomes were followed. RESULTS: Procedure was technically successful in 9 out of 10 patients and aborted in one patient due to cardiogenic shock. One patient had femoral closure device related complication. There was a statistically significant decrease in valvular gradient and increase in aortic valve area. 9 out of 10 patients recovered from acute episode and were discharged. 6 patients had improvement in NYHA class. 4 patients were subsequently able to receive TAVR. 90-day mortality occurred in 3 patients. There was no stroke or bradyarrhythmia peri-procedurally and no heart failure hospitalization at 90 days. CONCLUSION: Aortic valve lithotripsy-facilitated balloon valvuloplasty has reasonable feasibility, safety and technical reproducibility and acute clinical result. Hemodynamic effect is similar to that of balloon valvuloplasty reported in the literature. Subsequent Prognosis is not altered in critically ill patients.

4.
Cardiovasc Revasc Med ; 62: 105-118, 2024 May.
Article En | MEDLINE | ID: mdl-38212236

BACKGROUND: Percutaneous closure of aortic and ventricular pseudoaneurysms (PSA) has only been reported on a case report and series basis. In previous case reports, percutaneous closure has been performed successfully in patients of prohibitive surgical risk. This case series aims to show feasibility of percutaneous closure of aortic and ventricular pseudoaneurysm secondary to perivalvular leak (PVL) in a small patient population and the utility of multimodality imaging as an integral tool in procedural planning. This is the largest complex case series to date describing the feasibility and success rate of complex PSA closure, with a follow-up period of up to 4 years. MATERIAL AND METHODS: We performed institutional review and systemic literature review to identify all paravalvular leak cases with associated pseudoaneurysm formation for which a closure procedure was performed. Ten patients were identified. Pooled analysis for cases from institutional review (n = 10) and systemic literature review (n = 39) was performed. The success rate was 100 %. At 30-days, the mortality was 0 %. CONCLUSION: In paravalvular leak patients with subsequent pseudoaneurysm formation, exhaustive imaging evaluation is required for closure. However, it can be achievable with favorable rates of success.


Aneurysm, False , Heart Valve Prosthesis Implantation , Humans , Aneurysm, False/diagnostic imaging , Aneurysm, False/etiology , Aneurysm, False/therapy , Male , Female , Treatment Outcome , Aged , Middle Aged , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Aneurysm/diagnostic imaging , Heart Aneurysm/etiology , Heart Aneurysm/therapy , Cardiac Catheterization/adverse effects , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/surgery , Time Factors , Aged, 80 and over , Heart Valve Prosthesis , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Echocardiography, Transesophageal , Adult
6.
Echocardiography ; 40(11): 1285-1291, 2023 11.
Article En | MEDLINE | ID: mdl-37842844

Left ventricular pseudoaneurysm (PSA) after surgical aortic valve replacement (AVR) is a known but uncommon complication. It is associated with risks such as thromboembolism and life-threatening rupture. Surgical repair has traditionally been utilized in low-risk patients but transcatheter closure has become a promising therapeutic option. This case report describes the utility of multimodality imaging in pre-, intra-, and post-procedural evaluation of transcatheter PSA closure and is among the first to demonstrate the utility of 3D print model.


Aneurysm, False , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Aneurysm, False/diagnostic imaging , Aneurysm, False/surgery , Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/adverse effects , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/methods , Multimodal Imaging , Treatment Outcome
7.
Front Psychiatry ; 13: 803234, 2022.
Article En | MEDLINE | ID: mdl-35479490

Early-onset schizophrenia (EOS) shares many biological and clinical features with adult-onset schizophrenia (AOS), but may represent a unique subgroup with greater susceptibility for disease onset and worsened symptomatology and progression, which could potentially derive from exaggerated neurodevelopmental abnormalities. Neurobiological explanations of schizophrenia have emphasized the involvement of deep-brain structures, particularly alterations of the thalamus, which have been linked to core features of the disorder. The aim of this study was to compare thalamic shape abnormalities between EOS and AOS subjects and determine whether unique behavioral profiles related to these differences. It was hypothesized abnormal thalamic shape would be observed in anterior, mediodorsal and pulvinar regions in both schizophrenia groups relative to control subjects, but exacerbated in EOS. Magnetic resonance T1-weighted images were collected from adult individuals with EOS (n = 28), AOS (n = 33), and healthy control subjects (n = 60), as well as collection of clinical and cognitive measures. Large deformation high-dimensional brain mapping was used to obtain three-dimensional surfaces of the thalamus. General linear models were used to compare groups on surface shape features, and Pearson correlations were used to examine relationships between thalamic shape and behavioral measures. Results revealed both EOS and AOS groups demonstrated significant abnormal shape of anterior, lateral and pulvinar thalamic regions relative to CON (all p < 0.007). Relative to AOS, EOS exhibited exacerbated abnormalities in posterior lateral, mediodorsal and lateral geniculate thalamic regions (p = 0.003). Thalamic abnormalities related to worse episodic memory in EOS (p = 0.03) and worse working memory (p = 0.047) and executive functioning (p = 0003) in AOS. Overall, findings suggest thalamic abnormalities are a prominent feature in both early- and late-onset schizophrenia, but exaggerated in EOS and have different brain-behavior profiles for each. The persistence of these abnormalities in adult EOS patients suggests they may represent markers of disrupted neurodevelopment that uniquely relate to the clinical and cognitive aspects of the illness.

8.
Interv Cardiol Clin ; 10(4): 541-552, 2021 10.
Article En | MEDLINE | ID: mdl-34593116

The paucity of data regarding the use of transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) anatomy due to exclusion from pivotal studies and lack of studies assessing the long-term outcomes and valve performance continue to present a significant challenge as we expand TAVR to patients with BAV anatomy. This article discusses the important anatomic and clinical considerations in the selection and management of patients with BAV with TAVR and reviews the emerging evidence that increasingly suggests this procedure is safe, device success is excellent, and procedural outcomes are improving.


Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Constriction, Pathologic , Humans , Treatment Outcome
9.
JACC Case Rep ; 3(3): 366-369, 2021 Mar.
Article En | MEDLINE | ID: mdl-34317538

A 78-year-old woman with bioprosthetic mitral valve degeneration at high risk for reoperation was referred for transcatheter mitral valve replacement. We describe the use of a preemptive alcohol septal ablation pre-procedurally to minimize the risk of acute left ventricular outflow tract obstruction given the anticipated need for a bioprosthetic valve fracture. (Level of Difficulty: Advanced.).

11.
Circ Cardiovasc Interv ; 13(9): e009622, 2020 09.
Article En | MEDLINE | ID: mdl-32883106

The ongoing coronavirus disease 2019 pandemic has resulted in additional challenges for systems designed to perform expeditious primary percutaneous coronary intervention for patients presenting with ST-segment-elevation myocardial infarction. There are 2 important considerations: the guideline-recommended time goals were difficult to achieve for many patients in high-income countries even before the pandemic, and there is a steep increase in mortality when primary percutaneous coronary intervention cannot be delivered in a timely fashion. Although the use of fibrinolytic therapy has progressively decreased over the last several decades in high-income countries, in circumstances when delays in timely delivery of primary percutaneous coronary intervention are expected, a modern fibrinolytic-based pharmacoinvasive strategy may need to be considered. The purpose of this review is to systematically discuss the contemporary role of an evidence-based fibrinolytic reperfusion strategy as part of a pharmacoinvasive approach, in the context of the emerging coronavirus disease 2019 pandemic.


Fibrinolytic Agents/therapeutic use , ST Elevation Myocardial Infarction/drug therapy , COVID-19 , Coronavirus Infections , Humans , Pandemics , Patient Selection , Percutaneous Coronary Intervention , Pneumonia, Viral , ST Elevation Myocardial Infarction/surgery , Time Factors
12.
J Nucl Cardiol ; 25(3): 872-883, 2018 Jun.
Article En | MEDLINE | ID: mdl-27739037

BACKGROUND: HIV-infected persons develop coronary artery disease (CAD) more commonly and earlier than uninfected persons; however, the role of non-invasive testing to stratify CAD risk in HIV is not well defined. METHODS AND RESULTS: Patients were selected from a single-center electronic cohort of HIV-infected patients and uninfected controls matched 1:2 on age, sex, race, and type of cardiovascular testing performed. Patients with abnormal echocardiographic or nuclear stress testing who subsequently underwent coronary angiography were included. Logistic regressions were used to assess differences by HIV serostatus in two co-primary endpoints: (1) severe CAD (≥70% stenosis of at least one coronary artery) and (2) performance of percutaneous coronary intervention (PCI). HIV-infected patients (N = 189) were significantly more likely to undergo PCI following abnormal stress test when compared with uninfected persons (N = 319) after adjustment for demographics, CAD risk factors, previous coronary intervention, and stress test type (OR 1.85, 95% CI 1.12-3.04, P = 0.003). No associations between HIV serostatus and CAD were statistically significant, although there was a non-significant trend toward greater CAD for HIV-infected patients. CONCLUSIONS: HIV-infected patients with abnormal cardiovascular stress testing who underwent subsequent coronary angiography did not have a significantly greater CAD burden than uninfected controls, but were significantly more likely to receive PCI.


Coronary Artery Disease/epidemiology , HIV Infections/complications , Aged , Case-Control Studies , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Exercise Test , Female , HIV Infections/diagnostic imaging , Humans , Male , Middle Aged , Percutaneous Coronary Intervention , Severity of Illness Index
...